By using this website, you agree to the use of cookies as described in our Privacy Policy.

Authors: Siadat H, Bassir SH, Alikhasi M, Shayesteh YS, Khojasteh A, Monzavi A.
Implant Dent, Vol. Dec;21(6):, No., 2012,Page

Abstract

PURPOSE:

The aim of this study was to evaluate the effects of static magnetic fields (SMFs) on the implants immediately placed in fresh extraction sockets.

MATERIALS AND METHODS:

Twenty patients who were in need of 20 fixed implant-supported single crowns in the anterior maxilla were included. After tooth extraction, screw-type implants were placed immediately into fresh extraction sockets and were randomly covered with either magnetic abutment (test group) or conventional healing abutment (control group). Radio frequency analysis (RFA) was conducted at implant placement and after 1, 2, and 3 months. Marginal bone level changes were recorded 1, 2, and 3 months postoperatively.

RESULTS:

The RFA measurements showed a significant higher stability for implants in test group than that of control group after 1 month (P = 0.04). At month 2, less crestal bone loss was found in the test group (P = 0.03). However, at month 3, there was no significant difference between the groups for both parameters (P > 0.05).

CONCLUSION:

SMFs caused more noticeable increase in implant stability and less bone loss during the initial weeks of healing.

Related websites

6th floor, No.121, 10th Bostan st., Pasdaran ave., Tehran, Iran.
Tel: (+9821) 22586341- 22586401
Fax: (+9821) 22586573
Email: info@drsiadat.com
Free Consultation: 09101484671
@dr.siadat